The Control Assign function on Oxygen Series (blue & silver) keyboards assigns a MIDI controller message (MIDI CC) to a selected controller.
To assign a MIDI CC to a controller:
- Press a button or move a knob/slider to select the control
- Press the Advanced Function button.
- Press the Control Assign key.
- Enter the MIDI CC value with the numeric keys.
- Press the Enter key.
The controller that is affected by the Control Assign function is always the last used controller. By default, controller 1 is selected. However, it is possible to alter the selected controller during edit mode by moving a different controller. As you enter a new MIDI CC assignment using the data entry keys, the LED will update to give feedback on the number that has been entered.
Please see this guide for assigning an Oxygen control to a specific MIDI channel. After programming your device, please see this article to store your changes to memroy.
Please see the appendix in the Oxygen user guide for a list of MIDI CC’s that are assignable. Note that we have expanded on the standard MIDI CC list. This is to include other useful MIDI messages such as NRPN messages, GM/GM2 Sys Ex and even some CC’s that define how the controller should operate. This simplifies programming such messages which are often complicated to program on other devices.