Home » Support » Knowledge Base » Knowledge Base

Knowledge Base

DAE error -6006 on launch (Win XP) Pro Tools M-Powered will not launch.
Text size [-] [+]

DAE error -6006 on launch of Pro Tools M-Powered on Win XP machine. Pro Tools will not launch.

The error means one of the following things happened:
 

  • The driver failed to start (i.e. we called start but didn’t get any callbacks for five seconds). If there’s a five second delay before the error message, then this is what’s going on.
  • The driver issued an unexpected / unsupported reset request. (That shouldn’t be the case for a FireWire device unless it gets hot-plugged or something.)
  • The driver failed to respond to getBufferSize or getSampleRate calls. Again, not likely if the device is otherwise healthy.
     


Most common causes are:
 


Here are some tips on further debugging:
 

  • Confirm that the device works as expected in some other ASIO application
  • Try a different FireWire port and/or cable
  • Select some *other* sound device as the default device in the control panel


For further assistance troubleshooting this issue, please contact Digidesign Tech Support.