Knowledge Base
DAE error -6006 on launch (Win XP) Pro Tools M-Powered will not launch.
Text size [-] [+]
Text size [-] [+]
DAE error -6006 on launch of Pro Tools M-Powered on Win XP machine. Pro Tools will not launch.
The error means one of the following things happened:
- The driver failed to start (i.e. we called start but didn’t get any callbacks for five seconds). If there’s a five second delay before the error message, then this is what’s going on.
- The driver issued an unexpected / unsupported reset request. (That shouldn’t be the case for a FireWire device unless it gets hot-plugged or something.)
- The driver failed to respond to getBufferSize or getSampleRate calls. Again, not likely if the device is otherwise healthy.
Most common causes are:
- Running Windows XP Service Pack 1. (Update to SP2)
- Incompatible FireWire card/port. (Install a qualified FireWire card)
- Insufficient Bus Power. (See this Knowledge Base article)
Here are some tips on further debugging:
- Confirm that the device works as expected in some other ASIO application
- Try a different FireWire port and/or cable
- Select some *other* sound device as the default device in the control panel
For further assistance troubleshooting this issue, please contact Digidesign Tech Support.